Cost effective
Wireless Multi-Circuit Monitoring Systems
Get remote visibility to see how your most critical equipment is operating with wireless multi-circuit monitors. Monitor high-energy loads in HVAC, IT, manufacturing, and more.
Your system will be customized to your needs, arrive fully configured, and install quickly thanks to our Monitoring Made to Measure system—saving you time and money.
Connect up to 72 current sensors to a monitor and measure voltage, amps, watts and more. Monitor full power, current only, or a mix of both.
Multi-Circuit Monitor Applications
The flexibility of these devices make them ideal for monitoring any type of equipment and informing a variety of business needs.
- Heating
- Air conditioning
- Computer room air handlers (CRAH) and conditioners (CRAC)
- Select circuits in a panel or PDU
- Automatic transfer switches (ATSs)
- Switchgear
- Other high energy loads
- Operations management
- Tenant submetering
- Cost allocation
- Data center PUE calculation
- Energy benchmarking
- Power forecasting
- Emergency preparedness
Monitoring Made to Measure Saves You Time and Money
Your monitoring system will be custom built to your specifications without added cost including:
- Voltage source type and quantity
- CT type, rating and quantity
- Custom wire lengths and colors
- Wire exit location
- Over-current protection
- Current-only, full power or a combination of both
Monitoring Made to Measure ensures your system fits your needs with no field configuration required. The faster you install, the sooner you get value from your monitoring data.
Benefits and Features
No IT configuration or field configuration required
Arrives fully customized to your specifications, cutting installation time in half
Measure a range of circuits (up to 72 CTs) with one device: full power, current only, or a combination of both
Choice of split core CTs, solid core CTs, or flexible Rogowski coil sensors
Monitor 15A to 4000A single- and three-phase circuits; 100V to 480V AC
Full power measures V, A, Ah, VA, W, Wh, PF, THDi, THDv, Hz
Current only measures A, Ah
Use anywhere: panelboard input feeds, select panelboard circuits, RPPs, switchgear, HVACs, generators, and other high energy loads
Compatible with any existing hardware and data is accessible via Modbus, BACnet, SNMP and other protocols or our EMX monitoring software
Wireless data transmission means no communications cables
Local OLED or LED displays
Uses secure private wireless protocol proven in critical facilities across over 25 industries worldwide
Multi-Circuit Monitors for
100 - 480/277V AC Input Voltage
BGS16
Models that support up to:
- 16 full power sensors
- 12 current-only sensors
100V to 480/277V voltage service
Supports 15A to 4000A split core CTs or Rogowski coil sensors
BGS32
Models that support up to:
- 16 full power sensors and 12 current-only sensors
- 24 full power sensors
- 32 full power sensors
100V to 480/277V voltage service
Supports 15A to 4000A split core CTs or Rogowski coil sensors
BGS72
Models that support up to:
- 40 full power sensors
- 48 full power sensors
- 56 full power sensors
- 64 full power sensors
- 72 full power sensors
100V to 480/277V voltage service
Supports 15A to 4000A split core CTs or Rogowski coil sensors
Multi-Circuit Monitors for
480V AC Delta Input Voltage
BGS9H
Models that support up to:
- 3 full power and 6 current-only sensors
- 6 full power sensors
480V 3-phase Delta voltage service
Supports 15A to 4000A split core CTs or Rogowski coil sensors
BGS15H
Models that support up to:
- 3 full power and 12 current-only sensors
- 6 full power and 6 current-only sensors
- 9 full power sensors
480V three-phase Delta voltage service
Supports 15A to 4000A split core CTs or Rogowski coil sensors
BGS18H
Models that support up to:
- 12 full power sensors
- 15 full power sensors
- 18 full power sensors
480V three-phase Delta voltage service
Supports 15A to 4000A split core CTs
BGS27H
Models that support up to:
- 21 full power sensors
- 24 full power sensors
- 27 full power sensors
480V three-phase Delta voltage service
Supports 15A to 4000A split core CTs
Sophisticated Panel Mapping Capability Available
Part of a multi-circuit monitoring installation involves defining the circuit mix and making that information usable in your monitoring application.
Our panel editor makes it easy to specify the breaker rating and mix of breaker positions per circuit on any panel layout.
... And Secure, Instant Access to Data
Data begins to flow immediately upon installation to your existing BMS (via SNMP, Modbus, Ethernet/IP or MTConnect) or the Packet Power EMX Energy Portal. Unlike many other monitoring solutions, there’s no waiting for expensive consultants to customize your system.
Packet Power’s wireless protocol was designed specifically for critical facilities with high security needs like data centers, financial service firms, government agencies, educational institutions, telcos, and colos.
Monitor Better and Easier
Packet Power is a leader in monitoring data centers. But our devices are valuable for any high-energy industry. They are a simple, cost-effective way to monitor single- and three-phase circuits up to 480V and 4000A. Match the type and amount of metering exactly to your needs. Your system will be customized and built to spec so installation will be fast, easy, and less expensive. Reduce down time and save.
The fully self-configuring wireless network protocol built exclusively for monitoring data means you pay less in setup and support costs. No need for communication cables or network configuration. Your monitoring network is completely separate from your wired data network for added security. Contact us to create a monitoring system designed just for you.